  | 型号规格:HSP-320单路输出开关电源 |  
  | 
    
      
        | 特点:全球适用AC输入电源
 内置PFC校正功能,PF>0.95
 100%满负荷烧机测试
 保护特性:短路/过载/过压/过温
 内置直流电扇强迫风冷
 内置风速控制
 工作频率100KHz
 1年保质期
 尺寸: 215*115*50mm (L*W*H)
 |  
 外壳编号:H007
 |  |  
| 型号 | HSP-320-5 | HSP-320-7.5 | HSP-320-12 | HSP-320-13.5 | HSP-320-15 | HSP-320-24 | HSP-320-27 | HSP-320-48 |  
| 输出 | 直流输出电压 | 5V | 7.5V | 12V | 13.5V | 15V | 24V | 27V | 48V |  
| 输出电压容差 | ±2% | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% |  
| 额定输出电流 | 55A | 40A | 25A | 22A | 20A | 13A | 11.7A | 6.7A |  
| 输出电流范围 | 0-55A | 0-40A | 0-25A | 0-22A | 0-20A | 0-13A | 0-11.7A | 0-6.7A |  
| 输出功率 | 275W | 300W | 300W | 297W | 300W | 312W | 315.9W | 321.6W |  
| 纹波及噪音 | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 240mVp-p |  
| 直流电压可调范围 | ±10% | ±20% | -16%,+10% | ±11% | -10%,+20% | -16%,+10% | -4%,+18% | -15%,+17% |  
| 启动、上升、保持时间 | 800ms,50ms,16ms/230VAC2500ms,50ms,16ms/115VAC 满载 |  
| 输入 | 输入电压范围 | 88~264VAC选择 47~63 Hz;120~370VDC |  
| 功率因数 | PF>0.95/230VAC,PF>0.98/115VAC满载 |  
| 交流输入电流 | 5A/115 VAC2.5A/230VAC |  
| 效率 | 79% | 83% | 86% | 86% | 86% | 87% | 88% | 89% |  
| 冲击电流 | 22A/115VAC40A/230VAC |  
| 漏电流 | <1 mA/240VAC |  
| 保护  特性 | 过载保护 | 105%~135% |  
| 保护方式:电流限制,自动恢复 |  
| 过电压保护 | 115%~135% |  
| 保护方式:切断输出,重新启动 |  
| 高温保护 | TSW1(功率管)温度在80±5 ℃(70℃±5 ℃5V)时切断输出,  在温度<80±5 ℃(70℃±5 ℃5V)后, O/I自动恢复工作状态. |  
| 环境 | 工作温度、湿度 | -20℃~+65℃;20%~90 %RH |  
| 保存温度、湿度 | -40℃~+85℃;10%~95 %RH |  
| 抗震性 | 10~500Hz,2G 10min./1周期,时长60分钟,各轴 |  
| 安全 | 耐压性 | 输入输出间:3KVAC输入与地:1.5KVAC输出与地:0.5KVAC |  
| 绝缘电阻 | 输入输出间,输入与地,输出与地:100M Ohms / 500VDC |  
| 符合  标准 | 安全标准 | 符合UL60950,TUV EN60950 |  
| EMC标准 | 符合EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024 |  
| 其它 | 重量 | 1.1Kg |  
| 包装 | 12pcs/14.0Kg/0.98CUFT |  
| 备注 | 1.所有参数在未特别指明时,都是在230VAC电压输入,额定负载和25℃条件下测量所得值。  2.纹波和噪声电压是在20MHz带宽示波器带12英寸双绞线末端加0.1μ和47μ电容时测得。  3.容差是电压设定误差、电压调整率和电流调整率之总和。  4.本电源考虑做为一个器件安装在最终设备上,该设备必须重新确认它的EMC指标。 |  
  |