240W Single Output Industrial DIN Rail Power Supply(HDR-240)  
Features:  
 Universal AC input/ full range
 Built-in active PFC function
 Protections: Short circuit/ Over load/ Over voltage/ Over   temperature
 Cooling by free air convection
 Can be installed on DIN rail TS-35/7.5 or 15
 LED indicator for power on
 100% full load burn-in test
 Fixed switching frequency at 100KHz
 3 years warranty
 Dimentsions: 125.5*125.2*100mm (W*H*D)
 
Data

   Short Form Datasheet
 
 
 
SPECIFICATIONS  
   
INPUT  
Voltage Range 88¡«264VAC47¡«63 Hz£» selected by switch 120¡«370VDC
AC Current 2.8A/115 V 1.4A/ 230V
Efficiency 84%(HDR-240-24);   85%(HDR-240-48)
Inrush Current Cold start 27A/115V 45A/230V
Leakage Current £¼3.5mA/240VAC
   
OUTPUT See Datasheet
   
PROTECTION  
Over Load 105%¡«150%
  Protection type: Constant current limiting, recovers automatically after fault condition is removed
Over Voltage 30-36V( HDR-240-24);54-60V(HDR-240-48)
  Protection type: Shut down o/p voltage, re-power on to recover
OVER TEMP. 100¡æ¡À5¡æ(TSW1)
  Protection type: Shut down o/p voltage, recovers automatically after temperature goes down
   
ENVIRONMENT  
Working Temp., Humidity -10¡æ¡«+70¡æ£»20%¡«90 %RH
Storage Temp., Humidity -20¡æ¡«+85¡æ£»10%¡«95 %RH
Vibration 10¡«500Hz£¬2G 10min./1cycle, period for 60min, each along X, Y, Z axes
   
SAFETY  
Withstand Voltage I/P-O/P: 3KVACI/P-FG: 1.5KVACO/P-FG: 0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC
   
STANDARD  
Safety Standard Design refer to UL508,UL60950-1£¬TUV EN60950-1
EMC Standard EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2(EN50082-2)
   
OTHERS  
Weight 1.2Kg
Packing 12pcs/15.5Kg/1.2CUFT
   
NOTE
1.  All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¡æ of ambient temperature.
 
2.  Ripple & noise are measured at 20MHz of bandwidth by using a 12¡åtwisted pair-wire terminated with a 0.1¦Ì & 47¦Ì         parallel capacitor.
 
3 .Tolerance: includes set up tolerance, line regulation and load regulation.
 
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must      be re-confirmed that it still meets EMC directives.
 
5 . Derating may be needed under low input voltages. Please check the derating curve for more details.
   
OUTPUT  
Model HDR-240-24 HDR-240-48
DC Voltage 24V 48V
Voltage Tolerance ¡À1% ¡À1%
Rated Current 10A 5A
Current Range 0-10A 0-5A
Rated Power 240W 240W
Ripple & Noise 80mVp-p 150mVp-p
DC Adjustment Range 24-48V 48-53V
Setup, Rise Time 800ms,40ms/230VAC at full load800ms,40ms/115VACat full load
Hold Time 24ms/230VAC24ms/115VAC at full load
   
     